Passivhaus Townhouses Are Underway in Philadelphia

Carriage horse stables once occupied the site where 27 Passivhaus units are being built by Onion Flats and Domani Developers

Posted on Oct 21 2013 by Scott Gibson

Onion Flats, a Philadelphia design-buildCompany that handles house design and construction. Since both services are provided by the same firm, integrated design can often be more easily achieved. firm that last year completed Pennsylvania's first certified PassivhausA residential building construction standard requiring very low levels of air leakage, very high levels of insulation, and windows with a very low U-factor. Developed in the early 1990s by Bo Adamson and Wolfgang Feist, the standard is now promoted by the Passivhaus Institut in Darmstadt, Germany. To meet the standard, a home must have an infiltration rate no greater than 0.60 AC/H @ 50 pascals, a maximum annual heating energy use of 15 kWh per square meter (4,755 Btu per square foot), a maximum annual cooling energy use of 15 kWh per square meter (1.39 kWh per square foot), and maximum source energy use for all purposes of 120 kWh per square meter (11.1 kWh per square foot). The standard recommends, but does not require, a maximum design heating load of 10 W per square meter and windows with a maximum U-factor of 0.14. The Passivhaus standard was developed for buildings in central and northern Europe; efforts are underway to clarify the best techniques to achieve the standard for buildings in hot climates. project, is transforming the one-time site of horse stables into a 27-unit townhouse project built to the Passivhaus standard.

The Stables was originally planned as a 70-unit condominium project, but that was derailed by the collapse of the housing industry in 2008, says Onion Flats President Tim McDonald. By the time the financial picture had improved, the company had become more interested in Passivhaus design and decided to rework the project. Its partner on the project is Domani Developers, also of Philadelphia.

The 2,500-square-foot townhouses, located in the Northern Liberties neighborhood just north of the Old City, will be divided into three "bars" of nine units each, McDonald says. Three modular units have been completed, and two of those have been sold. When the third unit has been sold, work will continue on the remaining units in the first bar, with the whole project potentially wrapped up in another year.

McDonald says a blower-door testTest used to determine a home’s airtightness: a powerful fan is mounted in an exterior door opening and used to pressurize or depressurize the house. By measuring the force needed to maintain a certain pressure difference, a measure of the home’s airtightness can be determined. Operating the blower door also exaggerates air leakage and permits a weatherization contractor to find and seal those leakage areas. on one of the completed units meets the airtightness requirements in the Passivhaus standard. "Everybody is confident that it's going to be certified," he said, "but that's a process that we have to go through."

In order to win certification, a Passivhaus building must show no more than 0.6 air changes per hour at a pressure difference of 50 pascals, while also demonstrating that (according to energy modeling software) that the building is likely to meet an energy consumption limit.

Townhouses also have the potential of meeting all of their own energy needs as net-zero energyProducing as much energy on an annual basis as one consumes on site, usually with renewable energy sources such as photovoltaics or small-scale wind turbines. structures. The townhouse currently on the market is listed at $749,000 by The McDonald Group.

Four levels, plus a finished basement

As described by a sales brochure for the project, each townhouse occupies a 16-ft. by 40-ft. footprint, not including a 26-ft. long carport in the back.

The first level is designed as a flexible space that could be what McDonald calls a "grandmother suite," a media room, an office or a fourth bedroom. The combined kitchen/dining/living area, plus an exterior terrace, take up the second floor, with two bedrooms, a bath, and laundry on the third floor. The fourth floor includes the master bedroom and bath, a walk-in closet, and a balcony.

There are three full baths, with optional upgrades that would make the 640-sq. ft. basement a finished living space and create a 170-sq. ft. rooftop terrace.

McDonald says the modular units making up the townhouses have 2x6 walls insulated with dense-packed cellulose and an additional 2 in. of XPSExtruded polystyrene. Highly insulating, water-resistant rigid foam insulation that is widely used above and below grade, such as on exterior walls and underneath concrete floor slabs. In North America, XPS is made with ozone-depleting HCFC-142b. XPS has higher density and R-value and lower vapor permeability than EPS rigid insulation. rigid foam on the exterior. The roof and floor also are insulated with a combination of cellulose and rigid foam, with total R-values of R-34 in the exterior walls and R-52 in the roof.

The doors and triple-glazed windows are manufactured by Intus.

To meet city requirements for storm-water management, the vegetated roof is designed to absorb and reuse the first 1 inch of rainfall. McDonald says. Onion Flats has a division called GRASS (Green Roofs and Solar Systems) that designs the roof system, which the company uses on its projects whenever possible.

Townhouses could be energy self-sufficient

Each townhouse is sold with a 4.23-kW photovoltaic(PV) Generation of electricity directly from sunlight. A photovoltaic cell has no moving parts; electrons are energized by sunlight and result in current flow. array, with the option of doubling capacity to 8.5 kW. With only two of the project's eventual 27 units occupied, there's not much of a track record on energy consumption to date, but McDonald says early signs are encouraging.

Townhouses are equipped with "heavy duty" monitoring systems that measure temperature, humidity, CO2 levels, and electricity consumption. In one unit that's been occupied for four months, energy consumption so far has been what's appropriate for a Passivhaus design, McDonald says. "If they keep going the way they've been going, they're really going to hit the mark," he says. "With that in mind, if they had an 8.5-kW system, if they doubled the size [of the array], then it could be a net-zero building."

Mechanical engineer Robert Benson designed the heating and cooling equipment, which McDonald says starts with a PTAC (packaged terminal air conditioner), a through-the-wall unit with the condenser and evaporator built into the same box. At The Stables, the units combine a heat pumpHeating and cooling system in which specialized refrigerant fluid in a sealed system is alternately evaporated and condensed, changing its state from liquid to vapor by altering its pressure; this phase change allows heat to be transferred into or out of the house. See air-source heat pump and ground-source heat pump. with an energy-recovery ventilator(ERV). The part of a balanced ventilation system that captures water vapor and heat from one airstream to condition another. In cold climates, water vapor captured from the outgoing airstream by ERVs can humidify incoming air. In hot-humid climates, ERVs can help maintain (but not reduce) the interior relative humidity as outside air is conditioned by the ERV., so each unit's duct system provides both heating and cooling as well as ventilation.

"It's a really, really cool system that was modeled off these products in Europe that we can't quite get yet here in the states called magic boxes," McDonald says. "They're about the size of a refrigerator and they do heating, cooling, ventilation, and domestic hot water."

Benson managed to get three of those functions out of his own design. Domestic hot water comes from a heat-pump water heaterAn appliance that uses an air-source heat pump to heat domestic hot water. Most heat-pump water heaters include an insulated tank equipped with an electric resistance element to provide backup heat whenever hot water demand exceeds the capacity of the heat pump. Since heat-pump water heaters extract heat from the air, they lower the temperature and humidity of the room in which they are installed. .

This is Onion Flat's second foray into Passivhaus construction. Its first was the three-unit Belfield town homes, which McDonald says was the first certified Passivhaus project in the state. It was finished in 2012 and is listed as a certified project by Germany's Passivhaus Institut.