Ten Ways to Improve a New Home

To keep future energy bills low, remember these ten key points

Posted on Nov 13 2009 by Martin Holladay, GBA Advisor

Buying an inefficient refrigerator is an expensive mistake. But at least the solution is simple: you can always buy a new refrigerator.

If you build an inefficient house, however, you may have an unfixable problem on your hands. Some newly built homes are so poorly designed, sited, and built that it would be cheaper to demolish them and start again than to correct all their flaws.

Assuming you get the details right from the start, the incremental cost of better energy features will be affordable, and you’ll still be smiling when energy prices double. But if you get the details wrong — if you choose cheap windows or build a leaky ceiling — you may be stuck with a white elephant.

The great tragedy of poorly built new homes is that many details that would have been easy to include at the time of construction are notoriously difficult to retrofit. To be sure your new home is an energy miser, not an energy hog, follow these ten important steps.

1. Design a small house
Avoid the temptation to build big, even if you think you can afford it. If you build a spare bedroom, remember that as long as you own the home, you’ll be paying taxes on it, heating it, cooling it, ventilating it, and vacuuming it. Maybe all you really need is a fold-out couch.

If you’ve ever been lucky enough to visit friends in Paris, Madrid, or Rome, you know that it’s possible to live a luxurious, civilized life in a small apartment. If it weren’t for building code requirements, I’d advise you to design your next house like a sailboat; failing that, at least use boat design principles for inspiration.

2. Orient the house properly
Passive solar design principles aren’t very complicated; a few simple steps can save significant amounts of energy.

If you’re building on a lot that is large enough to give you some flexibility, try to orient the house with the long axis aligned east-west. That provides the best orientation to take advantage of winter sunlight; it also makes it easier to avoid afternoon overheating.

In a cold climate, it’s best if your south elevation is unshaded. In a hot climate, however, you probably want to preserve as many trees as possible.

3. Plan your windows carefully
It’s painful to see an otherwise well-designed home with bad windows. Unfortunately, such houses are extremely common.

It’s the designer’s job to be sure that windows are properly sized, properly oriented, properly shaded, and properly glazed. Designers should always use energy modeling software when sizing windows.

If you drive through a new residential development in Texas or Georgia, it’s easy to tell which houses have oversized windows — just look for the curtains and shades. Many of these homeowners have paid for windows that might as well be covered with sheetrock — to avoid glare and overheating, the owners are forced to retreat behind curtains or blinds. If these homes had been properly designed, the windows would have been fewer, smaller, better shaded, and equipped with low-solar-gain glazing.

Windows in a hot climate — and west-facing windows in almost all climates — need glazing with a low solar heat gain coefficient (SHGC) — 0.30 or lower. In a hot climate, east- and west-facing windows should be minimized.

In climates with a significant heating season, it makes sense to orient about half of a home’s windows to the south. Cold-climate builders should seriously consider using triple glazing — at least for the north, east, and west windows, and perhaps for the south windows too. South-facing windows should have a high SHGC — 0.42 or higher.

In all climates, south-facing windows should be protected by a roof overhang that shades the windows during the hottest time of the year. Finally, all windows in all climates should include low-e glazing.

If your house is small and tight, you may be able to save some money on your heating and air conditioning equipment; use those savings to upgrade your windows. Good windows cost significantly more than run-of-the mill windows, and they’re worth every penny.

4. Design your air barrier
A home’s air barrier is like a three-dimensional balloon surrounding the home’s conditioned space. A builder needs to know exactly where that balloon is located, and exactly how it will be built.

The details of your air barrier design need to be finalized before the excavator shows up to dig your foundation. An air barrier is too important for job-site improvising by head-scratching framers, roofers, and window installers.

It’s not enough to say, “I’m using Tyvek as an air barrier.” If Tyvek is part of your air barrier system, you should be able to answer all of these questions before you begin building:

  • What happens at the base of the wall? How is the Tyvek tied in to your concrete foundation?
  • What happens at Tyvek seams?
  • What happens when Tyvek is cut for window installation?
  • What happens when the plumber installs a sill cock?
  • What happens at the top of the wall? How is the Tyvek tied to the ceiling air barrier?
  • Do any electrical boxes interrupt the air barrier?
  • How are floor and ceiling penetrations dealt with?

Of course, your air barrier may not include Tyvek — you might be using the airtight drywall approach, or you might be depending on spray polyurethane foam. That’s fine, as long as your air barrier system is designed ahead of time.

5. Install above-code insulation
The building code describes the worst house that can legally be built. If you build a home any worse than code requirements, you can be arrested or fined. That’s a pretty low bar, especially when it comes to insulation.

Architectural fads come and go, and many people live to regret certain choices — for example, a blue toilet, or fake exterior plastic quoins on the corners of a Dallas “chateau.” But nobody has ever regretted installing extra insulation.

If you can find a way to build your foundation, walls, and ceiling with 50% more insulation than the code minimum, or even twice as much, you’ll never regret it.

6. Install a drain-water heat-recovery device
A drain-water heat-recovery device (for example, the GFX or Power-Pipe) is a simple and cost-effective way to reduce the amount of energy used for domestic hot water. The typical unit consists of a 3- or 4-inch diameter copper drainpipe surrounded by a spiraling cocoon of 3/4-inch copper tubing. When installed vertically in a plumbing waste line, such a device can transfer about 55% of the heat energy in the drain water to the incoming supply water.

In a home where the residents prefer showers to baths, this simple device with no moving parts can save between 20% and 25% of the energy used for water heating. The price for a 3-inch diameter 5-foot long GFX unit is $710.

7. Keep all ducts inside the thermal envelope
Putting ductwork in an unconditioned attic should be a criminal offense. An attic is almost as cold as the exterior in winter, and can be much hotter than the exterior in the summer. During the summer, the difference between the cool air in the ducts and the surrounding attic air is much greater than the difference in temperature between the indoor and outdoor air. So why is attic ductwork insulated to only R-4 or R-6, while the attic floor gets R-38 or more?

The air in a supply duct is at a much higher pressure than the air inside or outside a house. Most duct seams leak, so a significant portion of the air passing through attic ducts typically leaks into the attic. Moreover, leaks in return ducts allow hot, humid attic air to be pulled into the air handler.

Needless to say, installing a furnace or air handler in an attic causes even more problems than merely installing ductwork there. In an energy-efficient home, all of the HVAC equipment and all of the ductwork must be located within the home’s conditioned space. No exceptions — end of story.

8. Upgrade the ventilation system
By now, most builders know that a tight home requires a mechanical ventilation system. If you’re building a very good home, its envelope should be really, really tight.

Do yourself a favor and invest in a high-quality ventilation system — in other words, a heat-recovery ventilator (HRV) or energy-recovery ventilator (ERV) with dedicated ventilation ductwork. The system should pull stale air from the bathrooms and laundry room and deliver fresh air to the living room and bedrooms.

The most efficient available ERV in the US is the RecoupAerator 200DX (equipped with an ECM motor) from UltimateAir.

9. Address lighting and appliances
For any home, the most cost-effective energy upgrade is to replace all incandescent bulbs with compact fluorescent lamps (CFLs). In recent years, the light output quality and dependability of CFLs have significantly improved. If you haven’t visited a lighting showroom recently, you’ll be surprised at the wide range of available fixtures specifically designed for CFLs. So make sure that every home you build is incandescent-free.

Lighting design is as much an art as a science. Here are some principles for effective lighting design:

  • It’s better to bounce light off the ceiling than aim light at the floor. Ceilings should be white.
  • Include lots of task lighting; there’s no need to light up the whole room like a baseball field if all you need is a reading light or work light.
  • Avoid the temptation to control a group of fixtures with a single switch. Individual toggle switches, one per fixture, should be installed in several locations to provide lighting flexibility. Don’t line up all of a room’s light switches in a single location like ducks in a row.
  • Avoid fixtures with elaborate shades or diffusers that limit the amount of light that leaves the fixture. It’s crazy to hide a nice 70-lumen-per-watt CFL behind a heavy lamp shade.

Selecting the right appliances and equipment can save a significant amounts of energy. Keep in mind:

  • Some appliances are optional. Instead of shopping for efficient equipment, you might want to consider omitting a dishwasher, clothes dryer, air conditioner, automatic irrigation system, or swimming pool pump. Less is more.
  • Elaborate heating equipment makes little sense in a small, well insulated house. If your heating bill is only $500 a year, you don’t need to spend tens of thousands of dollars on a ground-source heat pump or a radiant floor system.
  • Energy use is more important than energy efficiency. Energy Star labels can be misleading, since they usually compare an appliance only to other appliances of the same size. That’s why a large Energy Star refrigerator can use more electricity than a small refrigerator without an Energy Star label. The same problem exists with labeled televisions. Ignore the Energy Star label; instead, compare wattage or kilowatt-hours per year.

10. Perform a blower-door test
Air sealing is too important to leave to guesswork. The only way to know a home’s air leakage rate is to perform a blower-door test; that test should be performed on every single home you build.

If the test is performed before drywall is hung, and if you’re standing by during the test with lots of caulk and cans of spray foam, it won’t be too late to fix some of the defects revealed by the blower door.

It’s extremely challenging to build a house that meets the Passivhaus standard of 0.6 air changes per hour (ac/h) at 50 Pascals of depressurization. But even if you only reduce your air leakage rate down to 1.6 or 1.8 ac/h @ 50 Pa, your house will still be significantly tighter than most new homes.

For more information on blower-door testing, see “Blower Door Basics.”

Last week's blog: “Heating a Tight, Well-Insulated House.”


Tags: , , , , ,

Image Credits:

  1. Wyoming Home Performance With Energy Star program

1.
Fri, 11/13/2009 - 08:38

Typo in URL
by Keith Dibley

Helpful? 0

The drain-water heat-recovery device link to to GFX should be http://gfxtechnology.com/ - a slip of the fingers between R & F!


2.
Fri, 11/13/2009 - 08:42

Fixed it
by Martin Holladay, GBA Advisor

Helpful? 0

Keith,
Thanks. It's fixed.


3.
Fri, 11/13/2009 - 21:09

Above code insulation
by Doug McEvers

Helpful? 0

Extra wall insulation often comes in the form of high-R sheathing like extruded polystrene or polyisocyanurate foil faced sheets. Care must be taken with certain types of siding over high-R sheathing, the reflective value of these products is great and siding damage is possible. This may have been covered elsewhere on GBA, my builders experience says check for product compatibility when designing a wall system.


4.
Sat, 11/14/2009 - 00:03

Passive House
by Glenn

Helpful? 1

Is anyone using passive house techniques in Michigan? Is there any experience with SIP's? I am one of those living in a house (7 years old) that is cold, drafty and expensive to heat or cool. This was built by one of our better builders. While we lived in NY, I had great results with SIP's, but they haven't seemed to have caught on. Is there any reason for this?


5.
Sat, 11/14/2009 - 06:43

Foil behind siding
by Martin Holladay, GBA Advisor

Helpful? 0

Doug,
You're right that it's not a good idea to install siding tight to foam sheathing, but not for the reason you propose. It's not because of the "reflective" value of these foams (I'm guessing you're thinking of foil-faced polyisocyanurate). It's because foam, unlike wood, offers no moisture-buffering capabilities, and because foam, unlike wood, has a low vapor permeance. In other words, foam limits drying on the back side of the siding. Wood sidings do particularly poorly when installed directly over foam.

Fortunately, the solution is simple: install a rainscreen air space (either vertical strapping or a three-dimensional plastic drainage mat like Cedar Breather) between the foam sheathing and the siding. The rainscreen improves the moisture-management performance of the wall in many ways.

By the way, some types of siding, such as brick, perform much better when installed with foam sheathing than they do with OSB or plywood sheathing.


6.
Sat, 11/14/2009 - 06:58

Michigan builders and SIPs
by Martin Holladay, GBA Advisor

Helpful? 0

Glenn,
To answer your two questions:

1. Yes, some builders in Michigan are using passive house techniques. Here are two recent news articles on such builders:

http://www.miningjournal.net/page/content.detail/id/533703.html?nav=5126

http://www.mlive.com/business/ann-arbor/index.ssf/2009/05/passive_homes_...

2. There are at least two reasons why SIPs are not more widely used. The most important reason, in my view, is cost. Almost everyone who has looked into the matter (with the possible exception of some SIP manufacturers) has concluded that double 2x4 walls packed with cellulose insulation are significantly cheaper than SIPs.

There is one other possible reason. Some (but not all) builders are worried about the long-term durability of OSB, which is essential for the manufacture of the most common type of SIPs.


7.
Sat, 11/14/2009 - 11:24

Foam sheathing
by Doug McEvers

Helpful? -1

Martin, I have used foam sheathing on many projects with good success, for corner bracing i use 1/2" plywood covered with a thinner layer of foam. The reflective value I was referring to was installing a vinyl siding directly over polyisocyanurate. At least one siding manufacturer does not recommend it. As for wood siding, priming all sides and edges before installation will reduce cupping and blistering of paint.


8.
Mon, 11/16/2009 - 21:20

The parallel chord truss
by Doug McEvers

Helpful? -2

To add to Martin's insulation above code recommendation I would suggest the use of the "vaulted parallel chord truss" when a vaulted ceiling is desired. I have used them for about 10 years and the options available are endless. Seasonal movement seems to be very slight and with this truss design you get full insulation at the plate line. If you use a flat ceiling tie and a decent chord depth (24' or more), the lumber used is normally just 2x4 for spans of 30' or more. It is a great way to add volume within what would normally be attic space. I just did a project with a 28" chord depth and the new Owens Corning blown insulation gives me an R-80 continuous.


9.
Mon, 11/16/2009 - 21:26

Nice overview
by Carl Seville, GBA Advisor

Helpful? -1

Good job (not unexpected) in presenting the basics of doing it right. And many thanks for acknowledging warm climate issues in glazing and shading. You even mentioned Georgia!


10.
Tue, 11/17/2009 - 00:37

Adds to lst
by A. Vance Pool

Helpful? 0

Great list, well thought out. I live in the south so radiant barrier in the atic is a must with good attic ventilation. I like thermal mass walls, concrete, brick, CMU or the like since they act as a flywheel regulating hvac loads. Insulated concrete forms ((ICF) will reduce infiltration, take literally tons of HVAC requirements away, and concrete driveways will reduce the heat island effect, lower maintenance costs and improve stormwater runoff quality.


11.
Tue, 11/17/2009 - 17:57

Building smarter
by Tyler W. Yandow A.I.A. Architect

Helpful? 0

This is a very good list for anyone building a new house. I would add a couple of further thoughts. "Better" doesn't always have to cost more. For example Marvin's Integrity line of windows is priced significantly below their signature line but are much more energy efficient because their frames and sash are made of "pull-truded" fiberglass. Although Integrity doesn't offer custom options, there are more than enough choices to create an aesthetically pleasing design.

One of my favorite references for energy efficient framing details is Joseph Lstiburek's "Builders Guide to Cold Climates." This book is filled with construction details which minimize heat loss, particularly through infiltration. Many people are unaware that infiltration (heat loss through small holes and cracks) is the most significant source of heat loss in a house. Yes, good insulation makes a difference, but a well sealed house goes much farther.

One other common mistake is to over size the heating source, usually a boiler or furnace. Plumbers are notorious for this if left to their own devices. Beside running inefficienlty, an oversized heating plant costs more.

One of the most effective ways to reduce energy costs and the overall impact of building on the evironment is to build a smaller house. Besides using less fuel to heat and cool, it produces less construction waste, takes less time to build, and allows one to use better quality materials for the same money as a bigger house which uses "spec house" grade materials and fixtures. If you really want to go green, use locally sourced materials that don't have to be trucked half way across the country. This supports local business and reduces the overall carbon footprint of your house by reducing air polution from trucks.

And last but not least, don't use vinyl siding! Besides essentially wrapping your house in a plastic bag, never allowing any moisture in the walls to escape (a sure invitation for rot and mold), the toxic waste created during the manufacturing process is beyond belief.

Tyler W. Yandow A.I.A. Architect
www.yandowarchitects.com


12.
Wed, 11/18/2009 - 05:20

Correct, except about vinyl siding
by Martin Holladay, GBA Advisor

Helpful? 0

Tyler,
Thanks for your comments. I agree with most of your post, except your contention that using vinyl siding is equivalent to "essentially wrapping your house in a plastic bag, never allowing any moisture in the walls to escape."

In fact, vinyl siding is one of the best-ventilated siding options available. It is installed loosely on the wall, with what amounts to a built in rainscreen air gap. Tests have shown that water drains readily and rapidly from a vinyl-sided wall. The high rate of natural air flow in the air gap between the siding and the sheathing aids drying. Damp sheathing behind vinyl siding dries quickly.

These facts have been confirmed a number of times by many researchers, in the lab and in the field.

Finally, a caveat about Marvin Integrity windows: as far as I know, the line does not offer triple glazing.


13.
Wed, 11/18/2009 - 23:17

A couple of comments...
by Riversong

Helpful? 0

Martin, you say "The great tragedy of poorly built new homes is that many details that would have been easy to include at the time of construction are notoriously difficult to retrofit."

I agree, but I would definitely include radiant tubing in that category, particularly in a concrete slab floor. You get one chance to install PEX tubing when the concrete is poured at a cost of a few hundred dollars, and even adding it to a wood-framed floor later would be very disruptive and costly.

While I would agree that a ground-source heat pump in a small, tight house is overkill, I don't feel the same about radiant heat which is the most comfortable of all options (particularly with an otherwise cold-feeling concrete slab), the least intrusive into living space, the most uniform, and justified if it's sized properly and its heating plant also heats the domestic hot water.

And, while the UltimateAir ERV might be the most efficient on the US market, an ERV is generally not recommended for cold climates, but ideal for mixed or hot, humid climates. In a tight house in a cold environment, getting rid of humidity becomes a priority, not recycling it.


14.
Thu, 11/19/2009 - 06:08

Radiant tubing and ERVs
by Martin Holladay, GBA Advisor

Helpful? -1

Robert,
As I've begun to realize, there really is no resolution to the radiant-floor discussion. In spite of the fact that these heating systems are quite expensive compared to readily available alternatives, many builders and homeowners seem eager to install them. I believe that most of the warm-floor benefits can be achieved with airtight construction and increased floor insulation. A lot of the cold slabs that people keep comparing their expensive radiant floors to -- the dreaded "other guy's" floors -- are just poorly insulated, badly built slabs. Of course they're cold. But if the slab has thick, continuous sub-slab insulation, it's not going to be anywhere near as cold.

That said, if you want to install elaborate PEX tubing systems in your floors, and invest in circulating pumps, then nothing I write is likely to dissuade you. Suffice it to say that there are much less expensive ways to heat a well insulated house.

When it comes to ERVs, thousands of happy northerners are using ERVs as part of their mechanical ventilation system. The main reason these systems work so well is that there is very little difference in indoor humidity levels that can be attributed to ERVs (as compared to HRVs). In other words, many people (and ERV manufacturers) exaggerate the humidity effect caused by enthalpy wheels. So don't worry -- these devices aren't going to make northern houses too humid in the winter. Nor will they decrease indoor humidity much in the summer.

I've come to the conclusion that the big HRV versus ERV debate is silly. They both work about the same, because the amount of humidity transferred by these enthalpy wheels is trivial. Both devices work great at their core function, however -- ventilation.


15.
Thu, 11/19/2009 - 08:58

Great List!
by James Morgan

Helpful? 0

I like this list. A lot. I have just one and three-quarter quibbles:

# 6. This is surely a make-weight introduced to make the magic "Ten things YOU can do!" tagline. I can't imagine where the 20% to 25% energy cost saving comes from other than a manufacturer's fevered imagination. I suspect the 55% heat recovery number is in optimal conditions which are seldom achieved. If you're in the habit of taking long hot showers, I can see the marginal benefit: inflow/outflow synchronized, minimal storage losses waiting for the next refill cycle. But most other hot water uses are asynchronous - discharge not coordinated with tank refill. I doubt you'll get 55% in those conditions. I've also heard complaints about clogging with these devices. At $710 a shot plus installation (and many houses don't have 5' of vertical plumbing drop to install this thing) it's a poor substitute for other, simpler hot-water savings measures - low-flow showerheads & short well-insulated pipe runs to start.

#8. This is my half-quibble. I hate to see my clients spending money on the wrong things, and while in a super-tight house the case for mechanical ventilation can be very strong, I have seen the discretionary $$$ going to these kinds of super duper mechanicals INSTEAD OF to the envelope. I'd put it last on the list, with a strong regional caveat.

My quarter quibble is #9. I agree with everything you write, but I'd give lighting more emphasis, put it higher on the list in its own slot (hey, back to the magic ten if you dump #6!). Bad lighting design is the most common flaw I see in otherwise well-built homes. I cringe when I see a dozen recessed can lights doing a poor job of plugging a dozen unnecessary holes in an R50 ceiling and doing an equally poor job of lighting the room while they're at it. NO CAN LIGHTS EVER!

Going back for a moment to #6 & #8, I'm reminded of a point that Michael Pollan makes in his book "In Defense of Food". He sees stacks of vitamins, supplements and highly processed foods in the grocery aisles, their boxes with screaming labels, healthy this, low-fat that, while the really good-for-you stuff, unboxed and unlabeled in the produce section, has nothing to say for itself. (He calls this "the silence of the yams" - clever, huh?). Equally, most of the really, really important stuff in green building (build small, good site orientation & window placement, tight envelope, etc. etc. as Martin so wisely lists above) does not come neatly packaged in a box with a manufacturer's advertising budget behind it.


16.
Thu, 11/19/2009 - 09:53

GFX savings, mechanical ventilation, lighting design
by Martin Holladay, GBA Advisor

Helpful? 0

James,
Thanks for the kind words. I'd be happy to address your quibbles.

1. First, in regards to the order that the items were presented: I did not intend the first item on my list to be the most important and the last item on the list to be the least important. Rather, I listed the items in the chronological order that they usually occur, more or less -- which is to say that house design comes before plumbing rough-in, and plumbing rough-in comes before lighting installation and blower-door testing.

2. Here are my sources for measured energy savings attributable to the use of a drainwater heat recovery device:
a. Energy Design Update article, September 1997, reported field monitoring data gathered by researchers at Northeast Utilities in Hartford, Ct. The researchers reported 20% savings in hot water energy use.
b. Energy Design Update article, September 2000, reported on data gathered by ORNL in Duluth, Minnesota. Over a one-year period, GFX devices saved between 25% and 30% of hot water energy use.
c. Energy Design Update, March 2001, reported that energy consultant Bion Howard's measurements and calculations support 15% to 22% hot water energy savings from use of the GFX device.
d. Energy Design Update, October 2006, reported on a Manitoba Hydro study that found that on average, a GFX saved 16% of energy used for hot water; these savings averaged 21% in houses with gas water heaters. It was hypothesized that the lower savings in houses with electric water heaters were due in part to residents' decision to take longer showers, since the GFX in effect increased the limited hot water capacity of the electric water heaters.
I think my statement that "in a home where the residents prefer showers to baths" these devices "can save between 20% and 25% of the energy used for water heating" is defensible. Obviously the researchers' data include homes where residents prefer baths to showers; these homes report lower savings.
You are correct, of course, that hot water draws that do not include simultaneous drain use do not result in savings.

3. You're right that the economic argument in favor of HRVs and ERVs is stronger in cold climates than in hot climates. Nevertheless, I still argue that very small, very tight homes need excellent ventilation systems.

4. I think we are in agreement concerning lighting system design.

Again, thanks for your comments and kind words.


17.
Thu, 11/19/2009 - 12:17

Martin, thanks for the
by James Morgan

Helpful? 2

Martin, thanks for the clarifications and data sources. As my involvement in green construction is entirely at the design side I tend to rate energy interventions by relative value to my homeowner clients, and assumed your list was thus ranked. Understanding you have used the different yardstick of constructional order makes a great deal of sense.

The heat recovery data surprises me, I note that three of the four sources are specific to northern climates, perhaps the other one too. I wonder if this is another area for regional variance where our higher ambient temperature of incoming water here in N. Carolina would produce lesser results.

Another possibly regional issue - few of our projects have full basements or even deep crawl spaces, and even with those that do we can seldom clear as much as a couple of feet from lowest fixture drain to outflow to sewer or septic tank. Five feet of clear fall for the unit you describe would be a rare luxury. You do not comment on the clogging problems I have heard reported, and it occurs to me these may derive from using non-vertical units with slower flow rates in these constrained conditions. This is pure speculation on my part, I am not aware of anyone in our area who recommends or uses them on a regular basis, but your article prompts me to investigate further and I will ask around.


18.
Thu, 11/19/2009 - 13:00

Useful Information
by Grant Dorris

Helpful? 0

Martin,
Great post - as this is useful information that anyone can use. I live in middle Tennessee, which is not exactly the hotbed of green, or well-planned residential construction, for that matter. I spend a lot of time educating homeowners about what to look for in a home, and often use many of the items listed in your post. Herein, lies the rub – the homebuyer seldom has a choice in many of these items. They most often have to choose from what is available.

Homebuilders, on the other hand, have a choice. Many, but not all, of the builders I know are doing everything they can to drive their costs down and look at this list as something they will never be reimbursed for. Driving costs down is most often accompanied by a reduction in quality, but that is fodder for another day.

My question is how would you formulate a similar list for existing housing stock or to put useful information into the hands of homebuyers? I am convinced that change will occur when the consumer finally demands better (and knows what to demand). Until that happens, I fear that your assertion that “Some newly built homes are so poorly designed, sited, and built that it would be cheaper to demolish them and start again than to correct all their flaws” will keep repeating itself.

On a related note, I am working on putting together a “weatherization-for-dummies fact sheet” as a primer for people looking to retrofit their existing homes. Any thoughts you have on that would be appreciated as well.

Grant


19.
Thu, 11/19/2009 - 13:09

Existing houses
by Martin Holladay, GBA Advisor

Helpful? 0

Grant,
I hope to write a future blog on the topic of energy retrofit measures for existing houses.

In the meantime, you might want to see what I have already written on the topic:

"Deciphering the Tax Credits."

"The History of the Chainsaw Retrofit."

"Tackling the Plug Load Problem."

"Choosing an Energy-Efficient Television."


20.
Thu, 11/19/2009 - 14:28

smart-sized spaces, lighting
by Christopher Vlcek, Littlewolf Architecture

Helpful? 0

Martin, you make a good argument against the extra bedroom. The same can be said for other bonus rooms like studies, playrooms, media & recreation rooms, where a niche off a larger space might suffice. And yet, a bit of space for the future can also be of real benefit for changing owner/family/work configurations. How much is too little? As in all decisions, good design balance is important. Insulating an attic for future use might not have a very large energy cost. Keeping bedrooms small is another approach, making more use of shared spaces. Flexibility can also be built into home design by using sliding partitions & cabinets to hide & organize stuff, making multiple uses of a single room easier. This tilts back toward your sailboat as design inspiration.

For lighting, central direct/indirect fixtures that light the ceiling as well as below can be a great alternative to recessed lights, but finding good looking fixtures is not easy! Another key approach is to light vertical surfaces (walls & art & cabinets) that reflect light into the room and provide ambiance. Smart & simple fixture grouping & switch locations should provide for various room uses, with ganged-switches being an essential part of that approach. Insufficient ambient lighting can be a problem not easily remedied after the fact.


21.
Wed, 11/25/2009 - 21:37

wastewater heat recovery
by Ralph Doncaster

Helpful? 0

For houses in cold climates with on-site septic it will reduce the temperature of the sewage in the septic tank, likely to below 22C in the winter.
This site seems to indicate 22C as the point at which anaerobic activity noticeably slows.
http://www.energysavers.gov/your_workplace/farms_ranches/index.cfm/mytop...
Less active bacteria in the tank = less breakdown of solids = more frequent tank pumping requirements.


22.
Wed, 11/25/2009 - 22:01

radiant floor heating costs
by Ralph Doncaster

Helpful? 0

I emailed this to Alex Wilson 2 yrs ago when I read an article in which he advised against radiant floor heating:

Radiant floor heating can be much less expensive than you state in your article. My projected material costs for 1200 sq ft is well under $2000 (pex, insulation, circulation pump, electric water heater, etc.) Adding 4hrs @$50/hr for my plumber and 16hrs for a general laborer@$10/hr to run the piping and place the insulation, I'll likely spend less than $2400.

My actual costs came in under $1000; I did the plumbing & drilled the joists myself and had the kids help pulling the pex. An 80g hot water tank with 2x4500W elements functions as a boiler and provides domestic hot water. On the next house I build I'll probably go with a concrete topping coat instead; it will be even easier & cheaper than in-joist.

The house is in a 7000F heating degree-day climate where natural gas is not available so even with R25 walls, R50 ceilings, tight construction (1.1ACH@50Pa) the house costs a few times more than $500/yr to heat.


23.
Wed, 11/25/2009 - 22:10

when you need a HRV
by Ralph Doncaster

Helpful? 0

If you're not getting down to PassivHaus air tightness levels, a basic air exchanger without heat recovery is probably the best choice. Somewhere between 1.5-2.0ACH@50Pa the HRV doesn't save enough energy to justify the price premium.

http://markbrinkley.blogspot.com/2009/11/whither-mvhr.html


24.
Wed, 11/25/2009 - 22:23

house size
by Ralph Doncaster

Helpful? 1

Leed for homes looks at number of bedrooms, based on evidence that occupant count increases with number of bedrooms. Six people living in a 4000sq ft house is a much more efficient use of resources than six people split between 2 2000sq ft houses.
I built a house with 3700sq ft of heated space(excluding the 1700sq ft unfinished basement), but there are 8 people sleeping under our roof this week (normally 6).

I agree with the space efficiency idea though; with the benefit of hindsight I think I could have reduced the building footprint 10% and not impacted the usability with a few layout changes. Examples of space efficient floorplans that don't feel cramped (I've stayed in a friend's flat in London, and wouldn't live like that myself) would be appreciated.


25.
Thu, 11/26/2009 - 05:45

Electric water heaters as heat sources
by Martin Holladay, GBA Advisor

Helpful? -1

Ralph,
By connecting your PEX tubing to an electric resistance water heater with two 4,500-watt elements, you have chosen to heat your house with electric resistance heat.

As I wrote in my recent blog, "Heating a Tight, Well Insulated House," it sometimes makes sense to use electric resistance heat for space heating. But remember: (a) electricity is an expensive fuel; and (b) simple electric resistance baseboard heaters would be far cheaper than connecting an electric resistance water heater to PEX tubing.

If you want a space heating system that uses electricity for fuel, it would make much more sense to use ductless minisplits rather than an electric resistance water heater hooked up to an elaborate heat delivery system using PEX tubing and circulators. With a ductless minisplit, your fuel cost (electricity) would be between 33% and 50% of your current fuel cost.


26.
Thu, 11/26/2009 - 05:51

HRV
by Martin Holladay, GBA Advisor

Helpful? 0

Ralph,
I'm glad you agree that a mechanical ventilation system is essential. You're right that in some climates, an HRV is unnecessary.

Any ventilation system needs to be carefully designed; many mechanical ventilation systems are inefficient. Dangers include overventilation (which wastes the energy used to condition the indoor air), choosing inefficient fans (which use too much electricity), and designing bad ductwork.

An HRV will save energy compared to a mechanical ventilation system without heat recovery; if you choose the right model and program it correctly, it will move air efficiently. It's possible to design a mechanical ventilation system without heat recovery that costs less than an HRV, but it must be designed and programmed very carefully to minimize the system's energy use.

To learn more about designing ventilation systems, see "Designing a Good Ventilation System."


27.
Thu, 11/26/2009 - 05:59

Cool septic tanks
by Martin Holladay, GBA Advisor

Helpful? 0

Ralph,
You are exaggerating the disadvantages of cool septic tanks. Here in Vermont, I'm sure that many septic tanks are quite cool from January to May. I haven't put a thermometer in mine, but when the snow is thin, the tank gets cold.

Fortunately, spring always comes, and temperatures warm up during the summer, allowing more biological activity to occur. Because this alternating cycle of winter and summer is dependable, it works. I haven't heard that Vermonters' septic tanks are failing at a higher rate than septic tanks in Tennessee.


28.
Mon, 01/31/2011 - 08:04

In defense of irrigation systems
by Nathan Hauber

Helpful? 0

My observation is that most people like green grass and will water to achieve that regardless of whether they have an irrigation system or not. The interesting thing is that with an irrigation system a homeowner has the ability to control the timing and quantity of water applied. Whereas homeowners without irrigation systems are left to water during the hotter hours of the day and with too much water, homeowners with irrigations systems can water at the more efficient nighttime hours and easily limit the amount of water applied. The assumption here is the the homeowner with irrigation only uses it when needed, not mindlessly overwatering every night.


Register for a free account and join the conversation


Get a free account and join the conversation!
Become a GBA PRO!