‘Insulating’ Paint Merchants Dupe Gullible Homeowners

As Con Artists Profit From ‘Insulating’ Paint, the FTC is MIA

Posted on Sep 11 by Martin Holladay, GBA Advisor

Scammers have been selling “insulating” paint to gullible consumers for at least 27 years. Among the exaggerated claims made by distributors of these overpriced cans of paint is that the “low-e” coatings will “lower energy bills.” In addition to liquid paint, some fraudsters sell powders or paint additives, usually described as “miracle” products containing “micro-spheres” or “ceramic beads.”

Every few years, the sleepy regulators at the Federal Trade Commission (FTC) wake up long enough to send warning letters to the most egregious paint scammers. For example, in 2002 the FTC clamped down on Kryton Coatings International, a manufacturer which claimed that its paint was equivalent to 7 in. of fiberglass insulation. In March 2009, the FTC took action against Sumpolec, a marketer of coatings that were said to “equal R-100 insulating value.”

To Find Them, Just Lift a Few Rocks
In spite of these rare actions, however, marketers of “insulating” paint continue to thrive. With a simple Google search, any Web surfer can conjure up dozens of distributors of insulating paint, including those hawking Nansulate and Super Therm.

When I was the editor of Energy Design Update (EDU) — a position I held before joining the GBA team in November 2007 — I regularly exposed exaggerated energy claims made by paint manufacturers. My March 2004 article, “R-Value Scofflaws,” fingered the manufacturer of Super Therm. In June 2008, I wrote “Scam and Exaggeration Roundup,” an article highlighting exaggerations made by Nansulate. Although both articles were forwarded to the FTC, the agency has so far failed to act against either manufacturer.

“A Barrier to Heat Transfer”
The manufacturer of Nansulate — Industrial Nanotech of Naples, Florida —describes its flagship coating as a “liquid applied home insulation.” The company’s Web site falsely claims that “Nansulate is a new technology which insulates by means of low thermal conduction. … Residential customers typically report energy savings in the 20% to 40% range, which is of course dependent on each individual application. … You can boost the energy efficiency of your home by applying Nansulate to the interior walls, ceiling, and attic area. Nansulate will act as a barrier to all three methods of heat transfer — convective, conductive, and radiant. Radiant heat transfer is one of the most significant ways that heat is lost or gained from a home or building. Nansulate can be used as attic insulation, pipe insulation, wall insulation, and duct insulation in your home, helping you lower fuel bills.”

“R-19 Equivalent Insulator!”
If anything, the claims made for Super Therm are even more outlandish than those made for Nansulate. One Super Therm distributor, Eagle Specialized Coatings of Surrey, British Columbia, advertises that “Super Therm is a true ‘insulating’ coating and not just a reflective paint as are all the competing formulas in the market. Also tested by the Thermo Physical Research Laboratory for comparative R-19 equivalent insulation factor Super Therm blocked 92% of the heat. No other R-19 equivalent insulator can claim that! No Fiberglass, No Foam, No Cellulose, No other single ceramic paint!”

The manufacturer of Super Therm, Superior Products International of Shawnee, Kansas, claims that “Super Therm is a ceramic based, water-borne, insulating coating, designed to block heat load, moisture penetration, and air infiltration over a surface and to reduce energy costs. … Super Therm can provide energy savings of 20-70%. According to use and application. R-19 Equivalent Rating — Super Therm reflects over 95% of radiation from the sun replacing the 6 to 8 inches of traditional insulation to block initial heat load.”

How can these paint manufacturers get away with such wild exaggerations? Although the problem is due in part to the FTC’s lax enforcement of existing regulations, other factors play a role. According to an article in the September 2009 issue of EDU, “Such claims, as a rule, receive relatively little attention from energy experts. That’s partly because they are numerous enough that any attempt to debunk them individually would quickly develop into an open-ended game of Whack-a-Mole, and partly because the product claims are so outlandish that it’s difficult to imagine anyone taking them seriously.”

The Same As Ordinary Paint
Every researcher who has examined these products has concluded that there is no such thing as insulating paint. For example, tests at the Florida Solar Energy Center confirm that these paints are nothing special: “The Florida Solar Energy Center has tested ceramic paints and found them to have no significant advantage over ordinary paint in terms of their ability to retard heat gains through exterior building surfaces.”

The latest research lab to shine light on the insulating paint scammers is the Cold Climate Housing Research Center (CCHRC) in Fairbanks, Alaska. As explained in the September 2009 issue of EDU, CCHRC researchers decided to focus on two products that often generate customer complaints: Nansulate and Super Therm.

Are They Low-E?
In theory, the lower the emittance (emissivity) achieved by a paint, the better its performance. When CCHRC researchers tested the emittance of dried samples of Nansulate and Super Therm, however, they discovered that neither coating is low-e. An independent laboratory “tested the emittance of the coatings on three different samples for each coating. Super Therm had an average emittance of 0.9 and Nansulate had an average emittance of 0.92, which demonstrates that neither product is a good inhibitor of infrared radiant heat loss.”

The measured emittance values of these paints are truly dismal — far higher than the legal maximum for a radiant barrier, which is 0.10. (As it turns out, no paint on the market can meet the radiant barrier standard.) Some paint manufacturers classify their products as “radiation control coatings,” a category requiring an emissivity rating of 0.25 or less — a less stringent emissivity rating than radiant barriers. However, neither Nansulate nor Super Therm comes anywhere close to even this less stringent standard.

In any case, the emittance of residential paint is a moot point. A low-e coating is only effective if there is a large temperature difference between the surface being coated and the environment it faces. Such a large temperature difference can only occur on an uninsulated wall — and if your house has uninsulated walls, you have far more problems than can be solved by a few cans of paint.

Can Paint Have An R-Value?
In order to leave no stone unturned, the Alaska researchers measured the R-value of dried paint samples. Employing a Fox 314 heat flow meter, the researchers followed the standard ASTM C518 procedure for measuring R-value. (For more information on the ASTM C518 test, see “Understanding R-Value.”) Since a thin coat of dried paint is fragile, the paint was applied to 1/2-in. drywall before testing.

The results will undoubtedly disappoint the marketers of “insulating” paint. “Application of Super Therm increased the thermal conductivity of the gypsum board and therefore decreased the overall R-value,” the researchers reported. “Application of Nansulate resulted in no significant difference, as the change in thermal conductivity for the Nansulate-coated gypsum board is within the 1% measurement error of the Fox 314.”

If a Tree Falls In the Forest …
Of course, R-value results are often ridiculed by those selling “alternative” insulation products. As Jon Vara, the current editor of EDU, recently explained, “Manufacturers of insulating paints typically claim that, although their performance can’t be quantified by some standardized tests, they are effective in the real world. A possible explanation: they only insulate when no one is looking.”

In order to test this unlikely possibility, the Alaska researchers built three insulated test boxes lined with drywall. The drywall in the control box was painted with ordinary latex paint, while the two test boxes were painted with Nansulate and Super Therm. “The boxes were placed outside and the heaters operated overnight maintaining the inside temperature at an average of 74°F,” the researchers reported. “Data were not collected during the day to avoid interference from solar heat gain. This control testing was conducted over the course of a week to ascertain that the boxes required the same amount of energy to maintain temperature. … Following the painting, all three boxes were set up with the sensors and heaters just as they were in the control tests, and tested outside overnight once every two weeks for a 30-day period.”

“No Discernable Difference”
Guess what — paint is a lousy insulator. The CCHRC researchers concluded that “there was no discernable difference in the performance of the Super Therm or Nansulate in comparison to regular latex paint during the energy monitoring tests.”

The ball is now in the FTC’s court. Anyone who wants to give the FTC a nudge should contact Hampton Newsome, the FTC attorney who handles enforcement of the R-Value Rule. Newsome can be reached by phone at 202-326-2889; his e-mail address is hnewsome@ftc.gov.

The full CCHRC research report, “Product Test: Nansulate and Super Therm,” is available online.


Tags: , , , , , , ,

Image Credits:

  1. Cold Climate Housing Research Center
Sep 13, 2009
1:51 PM EDT

Some other misleading marketing
by Ed Voytovich

http://www.ftc.gov/opa/2009/03/rvalue.shtm

Sep 13, 2009
4:28 PM EDT

I wrote about this a year ago
by Lloyd Alter

I wrote about this a year ago in TreeHugger and it is remarkable reading the comments, this stuff is more religion than science. http://www.treehugger.com/files/2008/07/ceramic-insulating-paints.php

Sep 14, 2009
6:56 PM EDT

Comments on SUPER THERM
by J.E. Pritchett

When the manufacturer of SUPER THERM found out about the testing in Alaska, the office called the testing group to find out what was the purpose, the procedure, the authorization and the qualification to do the test. The manufacturer has ceramic products but states very plainly in their literature that SUPER THERM is a reflector of the radiation waves given from the sun. If someone needs to insulate in cold climates, they must use their other ceramic coatings designed specifically for this type of insulation requirement. The lab that did the testing did not contact the manufacturer to find out which product was best for what they were testing for. They chose to do testing on a product that was not qualified by the manufacturer to perform in this application. The ceramic coating designed for cold climates have been tested and have W/mK heat transfer numbers to qualify them for such uses. The lab said they got the product from someone?? who said it would work but the lab never did their due diligence to call the manufacturer to make sure they had the correct product. As we see, it is easy to criticize new technology and especially when there have been mispresentations in the market by many of the "reflective paint sellers". Those who have spend years testing and finding the combinations of ceramic compounds that can provide insulation effect don't need nor deserve this type of press just because it is easy to throw them into the same room with "reflective paints". As to testing or lack of testing referred by Mr. Holladay in this article, he has never seen nor brothered to review all the testing performed by ASTM laboratories on SUPER THERM and the other ceramic coatings marketed by Superior Products International. The Department of Energy Specialist in Tampa Florida did three tests on SUPER THERM in three separate parts of the US (Florida, Colorado and Texas) to determine if the product performed as stated, and it did. Bombardier Engineering did the most extensive insulation test (ASTM C 236) on a fiberglass board and then SUPER THERM to find SUPER THERM outperformed the fiberglass by as much as 148% improvement. Superior Products International has all the testing to prove the 20%-70% savings in testing and field studies covering over 100,000,000 sq.ft. of roofing in the books for review. I cannot speak for any of the other reflective or "insulation" coatings in the market, but I can definitely speak on the behalf of SUPER THERM and the other ceramic products in its' line and the company will not report facts and figures unless it can prove them, and it can. The products were developed while working in the oil fields and under the eyes of engineers which is why all the testing is at hand for review. The product line was not developed for home owners, even though they will work on homes, of course. The products were developed for the worst situations in petrochemical plants and work. To bring them into homes is not a stretch. The entire point is this: The products perform as the manufacture reports and can prove it. Taking a sample of one of the products to an Alaskan test lab that choose the wrong product for their climate is a failing of the lab and not the product. For Mr. Holladay to choose SUPER THERM for these unfounded accusations shows a total lack of research on his part. I do have a very legitimate question for him. Has he ever really checked the testing performed on fiberglass or the other "thick" materials to see how they are tested for their "R" rating, lack of humidity, specific single temperature point to represent all climates?? Did Mr. Holladay ever stop and question in his own house if he had an R 19 insulation using batt insulation, when in fact his studs are 2X4" allowing only 3" of batt and not the 6" that is the rated R19?? Acceptance of "status quo" allows only to criticize new developments while living in the Mother of all misconceptions. I would love to see him reserach the status quo insulation products and report his findings. We have, and would love to compare findings. This is a level playing field, and we would respectfully request we all play on it.

Sep 14, 2009
7:21 PM EDT

SUPER THERM
by J.E. Pritchett

I did forget to agree with anyone arguing that coatings do not have R values. The R value was designed for and by the fiberglass industry in the 70's to explain and sell the product. This is why an inch thickness must be in the formula mix. Coatings are not applied in inches and therefore cannot have "R" values. Unfortunately, because people have their heads wrapped around only the "R" value as a point of reference, the coating companies try to explain their effectiveness by using the R equivalant relationship which is perfectly acceptable in a comparison sense. Retailers do this every day and the FTC is fine with it. As to the FTC, they do require an ASTM test procedure as part of the requirements to qualify an insulation coating to show it does perform the heat blocking ability, and it is the ASTM C 236, which SUPER THERM has performed.
Blocking "heat load" is the key to controlling the amount of heat "avialable" for transfer. Either from sunlight (summer) radiation heat loads or convective heating (winter) interior loads to transfer to the cold exterior. If a wall or roof member can be coated to help block the loading of the heat, then the load and transfer is reduced and therefore offering the insulation effect most needed. When thick materials are designed to absorb heat and slowly transfer it (therefore the R value which is the measurement of how fast this will happen), this means you will lose and gain heat at a constant rate, and it increases with moisture and air flows in the walls and roofing (no typical construction is air tight). If the walls are sealed to help prevent the loading of moisture and reducing the air flow, physics tales over since a dry substrate is a better insulator than a wet one with a tighter air flow allowed. SUPER THERM is a tested "water barrier" to a 55 mph wind driven rain. It has a permability of 8.8 which allow it to breathe but helps to block wind flow. In summer, 40% of the A/C cost is dehumification, according to the Energy Specialist. Also, when the coating is applied over a wall, it is fully covered. Batt insulations only are installed between the studs which are ever 16". An infrared picture taken of a home in winter shows all the studs and joinst exposed in orange and yellow revealing the lost of heat every 16". This is covered by SUPER THERM and helps to prevent the lost or gain of heat in this "every 16" pattern.
There is more to insulation than the "R" rating and in the 21st century, the technologies are finding it.

Sep 15, 2009
5:29 AM EDT

Sorry, J. E. Pritchett
by Martin Holladay, GBA Advisor

J. E. Pritchett is mistaken.

1. Pritchett wonders whether the Cold Climate Housing Research Center had the “authorization” to perform this test. Fortunately, it is still possible for a research lab in the U.S. to test the performance of products without any authorization whatsoever.

2. Pritchett states, “The manufacturer has ceramic products but states very plainly in their literature that SUPER THERM is a reflector of the radiation waves given from the sun.” In fact, Super Therm’s manufacturer claims that Super Therm “Reduces energy costs and increases comfort by coating roofing and interior or exterior walls to keep heat in during winter or heat out during the summer.”

3. A Google search reveals that there is no testing laboratory in Tampa, Florida doing business as “Department of Energy Specialist.” It appears that the lab does not exist.

4. A Google search could find no evidence of a testing laboratory operating under the name “Bombadier Engineering.”

5. Pritchett says, “For Mr. Holladay to choose SUPER THERM for these unfounded accusations shows a total lack of research on his part.” In fact, I have been following the false claims of Super Therm marketers for many years. Although the details of the Super Therm claims have morphed over time, the themes are consistent. A few years ago, these marketers were claiming that Super Therm was “tested at Purdue University for comparative R19 insulation factor.” They have always targeted homeowners and made claims for cold climates; in earlier years, they claimed “Super Therm equals to an insulation value of R-10 ... The R-10 equivalency is a minimum in keeping heat or cold inside a room.”

6. Pritchett asks, “Has he [Holladay] ever really checked the testing performed on fiberglass or the other ‘thick’ materials to see how they are tested for their R-rating, lack of humidity, specific single temperature point to represent all climates?” The answer is yes. For seven years, I was editor of Energy Design Update. Probably no other periodical in the U.S. has more thoroughly investigated and reported on this issue. More recently, I wrote a blog on the topic: "Installing Fiberglass Right."

7. Perhaps most damning, Pritchett never suggests a mechanism whereby Super Therm might affect heat flow. Although he makes a passing reference to physics, he doesn't invoke physics to explain the effectiveness of his product. The only mechanism that physicists have proposed that might explain how a paint could affect the heat-transfer performance of a building assembly is the possibility that the paint lowers the emissivity of the surface to which it is applied. Sadly, Pritchett cannot make this claim, since the emissivity testing of Super Therm revealed that the dried paint has an emissivity of 0.9. The emissivity testing by the CCHRC researchers came up with a value very close to that claimed by the manufacturers of Super Therm. On the Super Therm Web site, the manufacturer notes, "Super Therm has a tested emissivity of .91." In other words, it's a high-e paint. Case closed.

Sep 15, 2009
1:23 PM EDT

The rebuttal from Mr. Holladay
by J.E. Pritchett

1. He is correct, a lab can test any product they chose without authorization. Problem is, would you think the lab would want to test a correct product to match up what they wanted to know. If it is for cold or for radiation which requires two different products. One product cannot do everything and this is simply a fact. So the lab tested a heat radiation product in a cold climate without sealing the exterior walls as we suggested when using this product. What does the result mean?? nothing.
2. All this information is correct. Records and studies are in the files showing the complete range of savings using SUPER THERM.
3. It is not a lab and never was. It is the South Flroida Energy Office and the specialist worked out of this office to travel and do their testings.
4. I never said Bombardier was a testing lab. They are an engineering group that is known worldwide. They had the SUPER THERM tested under the ASTM C236 to find out if it performed as marketed, and it proved it did. A compbination of labs were used to do this single test using VTEC labs to International Labs in Pa. to build the panels and set up the testing. Bombardier did the testing to find a replacement for fiberglass in their train cars. I am surprised he does not know who Bombardier is.
5. It was tested at Purdue, the testing was reported and the facts stand as they are. Comments such as "false claims" is words thrown against the wall to see if anything sticks. As I said, we started in the petrochemical field and only recently have looked at homes in our marketing. Again, total lack of knowledge on this subject shows.
6. If this is the case, then he agrees that compacting fiberglass does not reduce its' "R" rating. This is totally false. For a "R" 19, it must be 6" thick. If you compact it down to 3", you have reduced it down to R 9.5. This is physics and the way it is measured. So why has this never been questioned as to all the homes with 2"X4" construction and the code to be R19. As said, status quo is a comfortable seat.
7. The ceramic compounds are low density and will not absorb and load heat--- this is physics. A metal plate has high density and will absorb and hold heat. A piece of paper has low density and cannot absorb and hold heat like the metal. If the low density ceramics have a lower density than the paper, they do not absorb and hold heat, therefore repelling the heat off the surface which is why the emissivity of .92 is correct. If Mr. Holladay thinks this is all incorrect, then he needs to take on the entire Cool Roof Rating Council (CRRC) and Energy Star which claims the high emissivity as repelling heat.
8. I do agree with Mr. Holladay that this case is closed. To continue this conversation is at this point worthless due to the lack of knowledge and throwing half truths against a wall. For the readers and ourselves, it is a soap opera at this point of which no one is interested.

Sep 15, 2009
1:52 PM EDT

An invitation
by Martin Holladay, GBA Advisor

1. Pritchett now informs me the "The Department of Energy Specialist in Tampa Florida" is actually "the South Flroida Energy Office." I look forward to receiving a copy of this report. Please send it to me electronically (martin@greenbuildingadvisor.com) or by mail: Martin Holladay, P.O. Box 153, Sheffield, VT 05866.

2. I now learn that testing was commissioned by Bombadier, a manufacturer of train cars. Again, I welcome submission of their lab reports.

3. Ditto for any testing performed at Purdue University.

4. "Why has this [fiberglass insulation] never been questioned as to all the homes with 2"X4" construction and the code to be R19?" Actually, a great many energy experts, as well as Oak Ridge National Laboratory, have definitively shown that a 2x4 wall insulated with fiberglass insulation will have a lower whole-wall R-value than the R-value on the insulation package.

5. "The ceramic compounds are low density and will not absorb and load heat--- this is physics. A metal plate has high density and will absorb and hold heat. A piece of paper has low density and cannot absorb and hold heat like the metal. If the low density ceramics have a lower density than the paper, they do not absorb and hold heat." So far, so good. So the paint is low density. It's kind of fluffy. It's fluffier (more paper-like) than other paints, which are denser (more metal-like). It sounds like you are leading up to a fluffy-is-good explanation — as if the fluffy paint insulates the wall, like insulation. An interesting theory. There are only two problems: (a) the paint is so thin that its fluffiness is irrelevant; and (b) the paint is so thin that it has no measurable R-value.

6. For exterior paints in hot climates, a paint with a high solar reflectivity can lower cooling bills in some houses — especially poorly insulated houses. For interior surfaces in any climate, solar reflectivity is irrelevant. When it comes to emissivity — which is not the same a solar reflectivity — a low-e paint might slightly lower energy consumption when installed on the interior of an uninsulated building (for example, a steel-sided warehouse). A high-e paint like Super Therm, however, will never have any advantages in an interior application.

When it comes to the emissivity of a roof coating, the issue is complicated. "In warm and sunny climates highly emissive roof products can help reduce the cooling load on the building by releasing the remaining heat absorbed from the sun. However, there is also evidence that low emissivity may benefit those buildings located in colder climates by retaining heat and reducing the heating load. Research on the benefits of emissivity is ongoing." (http://www.energystar.gov/index.cfm?c=roof_prods.pr_roof_emissivity) Accordingly, a high-e paint like Super Therm, if used as a roof coating, makes more sense in a hot climate than a cold climate. None of these climatic subtleties, however, are conveyed by the Super Therm Web site.

Sep 15, 2009
2:16 PM EDT

Half-truths against a wall and convective heat off the wall
by Jon Vara

I find it interesting that Mr. Pritchett claims that the CCHRC tested the wrong product--that is, that Super Therm is not intended as a cold-climate insulator. Here's a quote from the FAQ section of the Super Therm page on the Superior Products II Web site:

Q: What s the value of Super Therm when used inside of buildings?
A: Super Therm has been tested to have an RE-19 value compared to traditional insulation. Super Therm has a tested emissivity of .91 which is the ability of the coating film to throw the interior convective heat off the wall and back into the room to main [sic] interior heat....

It would be interesting to hear Mr. Pritchett's explanation as to what, if anything, that passage means.

In an earlier response, Mr. Pritchett also notes that: "Coatings are not applied in inches and therefore cannot have "R" values. Unfortunately, because people have their heads wrapped around only the "R" value as a point of reference, the coating companies try to explain their effectiveness by using the R equivalant relationship which is perfectly acceptable in a comparison sense. RETAILERS DO THIS EVERY DAY AND THE FTC IS FINE WITH IT (emphasis added)."
Would Mr. Pritchett care to point to the section of the FTC's R-Value Rule that permits manufacturers to devise their own "R-value equivalents?" Perhaps his observation that the "FTC is fine with it" simply means that the agency rarely takes legal action against companies that make such claims.
Please don't rush off, Mr. Pritchett. There is so much more to talk about!

Sep 16, 2009
2:41 PM EDT

The FTC responds
by Martin Holladay, GBA Advisor

In response to my inquiry to the FTC, I received the following e-mail today from Robert M. Frisby, the assistant director of the Division of Enforcement of the Bureau of Consumer Protection at the Federal Trade Commission:

"Dear Mr. Holladay:
Thank you for providing information about the marketing practices of the manufacturers of Nansulate and Super Therm, and for your recent inquiry regarding whether the Commission plans to bring additional enforcement actions addressing the marketing of paints touted as having insulating
properties. We appreciate your interest and the time you have taken to provide us with information; however, we cannot disclose whether the Federal Trade Commission is investigating the marketers of Nansulate, Super Therm, or other paints purporting to have insulating properties.

Robert M. Frisby"

Sep 23, 2009
1:18 PM EDT

Heat Transfer 101
by Jimmy T

I am doing some research about how to insulate a container building and found this Super Therm ceramic insulative paint with a thickness of 10 mil or 0.01 inch and with a R 19 rating. First thought I think it is so outlandish and against my heat transfer theory. Second thought this must be from NASA since you never know what kind of new material development scientists can reach these days. Then I finally found their website (http://www.eaglecoatings.net/content/supertherm.htm) and this blog entry (http://www.greenbuildingadvisor.com/blogs/dept/musings/insulating-paint-...). Now I do have some serious doubts on this product after I read all these.

First, I can not find a single professional test report which should be in its original version under whatever ASTM or other test codes and with test performer’s name and signature, from their website among those big fonted colorful words,

Second, I believe Mr. Pritchett’s explanation about how the super therm works is not convincing.

Pritchett said: "The ceramic compounds are low density and will not absorb and load heat--- this is physics. A metal plate has high density and will absorb and hold heat. A piece of paper has low density and cannot absorb and hold heat like the metal. If the low density ceramics have a lower density than the paper, they do not absorb and hold heat."

As far as I know, insulation properties are all about electrical conductivity instead of density. Good thermal insulators are electrical insulators such as asbestos, glass, and ceramics. The only thing density comes to play is where in case composite materials designed for insulation (fiberglass, Styrofoam) have small dead air space to inhibit both conduction and internal convection. Lower density and higher volume may have better results.

Pritchett said: " If the low density ceramics have a lower density than the paper, they do not absorb and hold heat, therefore repelling the heat off the surface which is why the emissivity of .92 is correct."

As far as I know, high emissivity is not good for repelling the heat off the surface and it is a different concept from reflectivity. I copied some words from heat transfer textbook: all materials give off, or emit, energy by thermal radiation as a result of their temperature. The amount of energy radiated depends on the surface temperature and a property called the emissivity (also called the "emittance"). Emissivity is expressed as a number between zero (0) and one (1) at a given wavelength. The higher the emissivity, the greater the emitted radiation at that wavelength. A related material property is the reflectivity (also called the "reflectance"). This is a measure of how much energy is reflected by a material at a given wavelength. The reflectivity is also expressed as a number between 0 and 1 (or a percentage between 0 and 100%). At a given wavelength the emissivity and reflectivity values sum to 1. Radiant barrier materials must have low emissivity (usually 0.1 or less) at the wavelengths at which they are expected to function.

Third, I think the ceramic material used in NASA such as ceramic tile insulator is for fire protection and not for insulating purpose. Ceramic material is noncombustible and a good thermal mass. When the rocket takes off, those ceramic tiles are placed on the spaceship to protect it from flame. This ceramic material is good only for short time, huge temperature difference application or good for a sudden huge heat load. However, in building application, it is a different concept, the heat load is long time duration and with small temperature difference. If you still want to use ceramic material you have to make it several inches thick otherwise I rather use cheaper cement paste which give me almost equivalent results.

As for ceramic paint used in petrochemical industry, the purpose is probably anti-corrosion because of the excellent water repellent property of the ceramic.

Just my two cents.

Sep 24, 2009
12:32 AM EDT

Questions For Mr. Pritchett
by George Runkle

"The manufacturer has ceramic products but states very plainly in their literature that SUPER THERM is a reflector of the radiation waves given from the sun." - I've been getting calls from you guys constantly telling me how good your product is. This statement begs the obvious question - what happens in the structure from the hot ambient temperatures that surround it, and at night when it is hot? Also, why wouldn't a reflective paint work just as well?

The next question I have is about the information in this link: http://www.tprl.com/Stherm.htm

It pretty well tears apart the whole idea of insulating paint like your product. Interestingly enough, the company that owns this website is one who did the laboratory tests for you guys in the literature you sent me.

I think there is some very valid points brought up in the discussion here, and I'd like to see your responses.

George

Sep 24, 2009
4:48 AM EDT

Thanks for the link
by Martin Holladay, GBA Advisor

George,
Thanks for the link. You know a company is in trouble when the testing lab it hired has to devote a Web page to debunking the exaggerated claims made by the manufacturer that asked it to perform tests.

My two favorite lines:
"Much of the R-value being presented is being done out of context with the intent to mislead."

"In the summer it will reflect some of the direct sun's rays away from the building making it easier to cool but other white paints will also do this."

Sep 24, 2009
6:02 AM EDT

No lab reports yet
by Martin Holladay, GBA Advisor

Nine days after I asked Joseph Pritchett for copies of the lab reports from the South Florida Energy Office, the Bombadier train car manufacturing lab, and Purdue University, I still have not received any lab reports.

Sep 24, 2009
10:58 AM EDT

Lab Reports
by George Runkle

I went through the stuff I got from Super Therm and I don't have those lab reports either. I spent a lot of time reading the reports they did send me, and couldn't see how they came to the conclusion that the material has an "equivalent R-19" value. I've invited responses on my blog about the web page put up by TPRL. Perhaps I'm missing something.

George

Sep 24, 2009
7:07 PM EDT

Pritchett said: "The ceramic
by George Runkle

Pritchett said: "The ceramic compounds are low density and will not absorb and load heat--- this is physics. A metal plate has high density and will absorb and hold heat. A piece of paper has low density and cannot absorb and hold heat like the metal. If the low density ceramics have a lower density than the paper, they do not absorb and hold heat."
He is correct about that - heat doesn't travel as fast through a low density material as it does through a high density material. However, it takes some thickness to slow down the heat transfer, which is why you have to put a number of inches of fiberglass insulation in your attic.

So, the question becomes, and has never been answered to me - how can a very thin coating of less dense material be able to slow down the heat transfer? Can you give me an equation that gives the thermal transfer of the material so I could use it to determine how well it will work?

The thermal conductivity that I see in the lab tests that you provide in your literature is 4.5 btu-in/hr-ft2) Figure 7, page 15 in TPRL's report for your company dated May 7, 1997. For 3 inches (which is much thicker than you would paint on), I get an R value of 0.667. Am I calculating this wrong? Can you explain what is wrong with my calculation without rhetorical statements or personal insults? I await your answer.

Thanks,
George

Sep 26, 2009
1:48 AM EDT

Nansulate
by Anonymous

Hi, I read with great interest your article on Nansulate and Super Therm. Super Therm I have never heard of but Nansulate I actually purchased last year. With it we painted the ceilings and walls in about 1500 sqft of space. Before I committed to such a large amount for my private home, I purchased a single gallon and used it on a kitchen cookie sheet. I painted half of it and waited 30 days-I think the instructions are actually 60 days for curing-but after 30 days I heated the cookie sheet on my gas stove then dropped water droplets on the coated and uncoated sides. The uncoated side immediately boiled and evaporated while the coated side just sat there and didn't even boil. That convinced me something is at work w/ the heat transfer. But is of greater importance to the home owner is the savings received on the electric and gas bills for the year. I think w/ Nansulate if people wait the 60 days to cure-I think the test presented in your case didn't wait that long-if people wait the 60 days, they will see energy savings. As for me and my house, we are convinced it works and are enjoying the benefits of Nansulate :)

Sep 26, 2009
5:13 AM EDT

Anonymous
by Martin Holladay, GBA Advisor

Dear Anonymous,

1. Forgive my suspicious nature, but why do I have a sneaking suspicion that an anonymous posting that tells a story praising the effectiveness of a product that most experts describe as a scam MIGHT be written by someone associated with Nansulate?

2. Even if your anecdote is true, it tells us nothing about the effectiveness of Nansulate or the likelihood that Nansulate will reduce energy bills. The cookie-sheet test results might be identical for ANY paint, for all I know. If I wanted, I could attach 1/2-inch drywall to one side of a cookie sheet with sheet-metal screws, and do the same test. Of course water droplets will evaporate faster from a the hot bare metal of a cookie sheet than they will from 1/2-inch drywall! But I wouldn't want to depend on 1/2-inch drywall to insulate my house.

Sep 26, 2009
1:03 PM EDT

The cookie sheet test
by Jimmy T

That is what I was talking about. The ceramic paint may be good at short time duration, large heat load application such as fire protection. However, it doesn't work for long time duration, small heat load application such as insulating your home unless your house is frequently got burned? like a furnace? otherwise, I would not insulate my house by cookie sheets with a ceramic coating on them. :)

Sep 26, 2009
3:23 PM EDT

The Cookie Sheet Test and Court
by George Runkle

OK, I design the HVAC system of a building based on the great information you guys have just given me for Super Therm and Nansulate. I use an "R Equivalent" of 19 for my calcs, using the ASHRAE manual and the International Mechanical Code. The building owner decides the HVAC system doesn't work, and sues me for Gross Negligence. When I go to court, the opposing attorney will ask me the following questions:
Attorney - What "R" value did you use in your calculations?
Me - uh, well, an "R equivalent" of 19.
Attorney - and...Mr. Runkle (they always address you this way when they are going for your throat), what is "R equivalent"?
Me - well, it was described in Super Therm's literature, and this guy did a cookie sheet test
Attorney - what recognized body defines "R equivalent" ASTM? International Code Council? ASHRAE? ANSI?
Me - well, um, Super Therm said...
Attorney - I assume Super Therm had a definition of "R Equivalent" that was established by a recognized body?
Me - uh, well they ...
Attorney - SO, you used a value that the manufacturer assigned to this product that has no basis in any independent lab testing or definition by any code body?
Me - well they said...
Attorney - what engineering principle does "they said" come under Mr. Runkle?
Attorney - oh, and what ASTM standard is the "cookie sheet test?"

See where I'm going on this? I would be paying a huge claim, my insurance company might cancel my policy, and there would be grounds for the Board of Professional Engineers to go after me. We haven't had any kind of reference to a recognized standard for this stuff. There literature they gave me is full of tests that cover a lot of things, but none of them lead logically to a R-19 value. Even the hokey "R Equivalent" has no logic that I personally could follow, and there is no definition of "R Equivalent" except for us to believe that this stuff works.

For the cookie sheet test (which would get me laughed out of court), I can heat up a cookie sheet to the temperature that it boils water, and handle the think with a 1/4" thick pot holder out of the kitchen drawer. Maybe we could use pot holders for insulation.

Now, for the home owner's "great savings" - how much is great, and has he taken into account differences in climate that occur over one year to another? In true tracking of energy savings you need to adjust your figures to the degree days that have gone by to that point in the year, otherwise what you think you have saved is meaningless.

So, in fairness, I ask that you guys please answer a few pertinent questions:
- What is R Equivalent? Who defined it?
- What equations can I use for the heat transfer across the material?
- Have you had any independent labs test these kind of assumptions?

George

Sep 26, 2009
5:29 PM EDT

Insulating paint court case
by Martin Holladay, GBA Advisor

I heard a story about a court case revolving around “insulating” paint. Unfortunately, I have been unable to confirm it. Of course, I would be delighted if someone were to read the words that follow, recognize the case, and contact me with confirmation. Since I don’t have confirmation, we’ll have to introduce this story as an urban fable. It was told to me as truth. The story is too delicious for me not to introduce it.

Here’s how the fable goes: a Long Island builder reads about “insulating” paint on the Internet, gets excited, and signs on as a distributor for the product. A little later, his mother contacts him to build her a house. The paint distributor, convinced of the efficacy of Miracle Whip 2000, or whatever the brand was, builds his mom a house with 2x4 walls, without any insulation at all. He paints the interior with Miracle Whip 2000. He paints the siding with Miracle Whip 2000. Since the paint has an “equivalent R-value” of 19, he assures his elderly mom that her walls have an R-value of 38.

Mom moves in. Cold weather arrives, and her furnace is running 24 hours a day. Mom is shivering, because the house never gets warmer than 55°F or 60°F. Poor mom; she can’t sue her son. But she does call him up on the phone.

According to the story, the son did what any loyal Miracle Whip 2000 distributor would do: he sued his HVAC installer for installing too small a furnace. The storyteller didn’t know the outcome of the case.

Sep 28, 2009
5:40 PM EDT

Field test
by Blake Jensen

I bought some ceramic bead reflecting stuff for my garage door last may. I followed the directions and applied the paint to one of my doors. The next day I did a temperature test on it and the door next to it. To my surprise the 2 doors had a distinct temperature difference. Unfortunately the door I painted was 6 degrees hotter than the unpainted door. That sucks. I had wanted to, at that point in time, paint my house with the product but I did not after the test that I performed. Part of me wants to do one wall and paint half with treated paint and the other with plain un-treated paint and then use my IR camera to see is there is any difference. Maybe when it’s not 109 outside I will.

Sep 29, 2009
3:30 PM EDT

Unfortunate home owners
by Ben Ainslie

Before entering the field of green product sales I was a painter/contractor for over a decade. I think the worst part about these products is that they may actually appear to work, and most of the time seeing is believing. The best to insulators on earth are dead air spaces and vacuums. A well caulked paint job will create a vacuum and will definitly save on a heating bill. So now you have a company that is marketing their product, and not the handy work of the painter as an insulator. So the work is done and, yup you guessed it the homeowners heating bill goes down. Next thing you know Mr. or Mrs. Homeowner is calling everyone they know to tell them about how great their miracle paint is. The sad truth is the local paint contractor could have given them the same energy savings with a beautiful finish for what I am sure would be a fraction of the cost just by doing his job right.

Jan 4, 2010
4:50 PM EST

Thanks for the blog
by Ken Matson

You just saved me days or weeks of research and disappointment. Thanks very much for the public forum. I will have to insulate my "new to me" shipping container the "old school" way.

Jun 8, 2010
10:44 PM EDT

Ceramic Insulating Coatings
by Silverbullet

I am a 40 year solar professional. Recently, with the completion of a new prototype ready for certification, we looked at ceramic type coatings. It would be much less expensive in production runs rather than using foam products which also require a protective cover to keep from the exterior foam being damaged.
After speaking with a number of companies who manufacture/distribute these products, I still have no solid science nor answers. Its a shell game. The most notorious line is, "Our products may have different results on different applications." DOH! Well then, that taken into consideration, WHAT CAN I EXPECT? Then I get shuffled to some 'engineer in the field' who is a professional at CYA!
Simple question to all: If I build two identical boxes using aluminum, each to hold a gallon of water heated to 200F, place thermistors in each for monitoring, place both in a freezer, what can I expect to see?
NO RESPONSES TO DATE!
Rather than take a chance of spending $9000.00 for certification risking this material will work, I am in the process of building the two boxes. I have many different types of testing equipment to measure the results since I once owned an electronics company that designed and built systems for the solar industry.
If you would like to see the results of my tests, please send me an email: appliedenvironmentals@gmail.com.
Expect to wait several weeks for our results to be reviewed and possibly retested for absolutely accurate results.
This will certainly end these discussions once and for all in terms of the benefits of holding heat in.
Why on earth hasnt someone done this in the thirty years these products have been on the market!!??
Regards,
Sam

Jun 9, 2010
5:28 AM EDT

Testing "insulating" paint
by Martin Holladay, GBA Advisor

Sam,
Go ahead and run your backyard tests. Please share your results with the rest of us.

In fact, many people have conducted similar tests. After all, the blog that you are commenting on describes an elaborate series of tests to determine the performance effects, if any, of so-called "insulating" paint or "ceramic" paint.

As I have reported many times in many articles, these tests have very consistent results: insulating paint performs exactly the same as ordinary paint. That's why researchers have concluded that these paint salesmen are scam artists.

Jun 23, 2010
10:31 PM EDT

On a lighter side
by Paul Badger

Assuming there will be more space flights in the future and more "Shuttles" will be made to make these trips , could this paint be used to cover the surfaces that are now covered by expensive delicate ceramic plates? Would it not be cheaper and easier to repair?. ( How many coats would it take to create the equivalent "R" value?
Maybe Mr. Pritchett could be convinced to be on the first test flight . I would pay extra to see that.

Is it possible that somebody has actually put together a factory and created and produced a product that produces enough income to actually make the investment worthwhile? Who are the People buying this stuff?
If this whole discussion is not a joke than I am truly embarrassed.

Jul 18, 2010
11:29 AM EDT

Who Buys This Stuff
by Anonymous

My house was built in 1960, with 2-3 inches of insulation in the walls and ceiling. A hip roof was constructed over the old flat roof, but the old roof was left intact, which means that it is fully ventilated underneath, and adding insulation over the old roof and under the new one would do no good. There is not sufficient room to stand over the old roof to remove it. When I bought the house in 1988, heating costs were not as bad as today. I'm desperate. That's why I would like to read that this stuff works, but i guess I'm still waiting.

Jul 18, 2010
1:27 PM EDT

Response to Anonymous
by Martin Holladay, GBA Advisor

Anonymous,
As you may have guessed, there are apparently enough people out there who "would like to read that this stuff works" to keep these paint scammers in business.

There is probably a way to convert your new ventilated roof to an unventilated roof, and there is probably a way to insulate the space between the old roof and the new roof. However, it's impossible to devise the details over the Internet. You'll need to consult with an experienced insulation contractor.

Jul 20, 2010
11:23 PM EDT

Ceramic Paints
by Bob Ellenberg

I missed this last fall but since there is recent interest I'll take the time to share my experience in 2006 with Supertherm and Mascoat. Mascot is a reputable manufacturer of industrial coatings in Houston that work the way they say they will. But let me tell you about Supertherm first.

I am pretty thorough when I explore things but I do not have the engineering knowledge to evaluate this stuff. I was first interested when it was being used by some who were building houses with intermodal steel building units several years ago. There were licensed design professionals using and touting this stuff so I assumed it had to be legitimate. I got all the info. from Supertherm, studied it, called and asked lots of questions on several occassions. Meanwhile I had hired an engineer to do some structural calculations and mentioned to him my excitement about this product and he expressed his skepticism (most of his back ground is in thermo dynamics). As a result I gave him all the literature from Supertherm and after reviewing it he basically said it was hocus pocus and expained why their claims were false. I really wanted to believe in this stuff so I went back to them again, posed questions about all the things he had told me and their "engineer" finally told me if I didn't believe them to conduct my own test and I would see that it really worked.

Meanwhile I had searched for other coatings and one I came across was Weather Bloc by Mascoat. After reading all of their literature I called and stated talking to them. In a nut shell they said the Supertherm people were scam artists; that the Mascoat coatings could be very useful in some applications,; that in some applications "R-equivalency" had some validity but that there was no standards and therefore it could not be relied on. Since they came across as honest and not selling snake oil, I decided to include them in my tests.

These were not laboratory tests but we did a pretty good job and I had my engineer involved in helping me set them up. I was convinced that they might have some application in reflecting some forms of heat but I was interested in how they would perform (if at all) the way they would be applied in a house.

I bought 3 steel boxes 1'x1'x3' that were open on one long side. I cut a 4"x4" hole in each one and sealed in a plexiglass window. Next I built a OSB bottom that could be sealed in place. I fitted each box with a 100 watt bulb (heater) and fastened a thermometer to the OSB floor where it could be seen through the window. We were in Northern New Mexico in early spring so it got pretty cold at night. We placed the steel boxes on each base and observed the thermometers (inside my garage, no wind or sun) with and without the bulbs on to see that they were all calibrated and they all read within 1 degree under all conditions.

For the control box of conventional insulation, I chose expanded styrene foam. This is generally accepted as one of the better conventional insulation materials available and it would be simple to fasten it to the exterior of the steel box with calk and adhesive. The minimum requirements for wall insulation in my home climate zone is R-19 and R-38 for the ceiling. I affixed two layers of foam rated at R-10 to the walls for R-20 and four layers of R-10 to the roof for R40. For a floor I attached a single layer of R-10 as I decided to make all the floors of the test boxes insulated the same. This was because if I used the Supertherm or Mascoat I would be using them on the walls and roof but not on the floor.

For the Supertherm box I put two coats both inside and out. They claim this will give an R value equivalency of R-28.5. I was very careful about the application and had several conversations with Supertherm's engineer to be certain I would be doing it correctly. I purchased a mil thickness gauge and carefully documented that I was applying it as instructed. I also compared the quantity of material we used to the surface area that we had covered which indicated we had applied it to the thickness as specified or perhaps a little thicker. This required two coats and we carefully documented the thickness as we applied them.

For the Mascoat box we also applied it as instructed by the manufacturer. The Mascoat Weather Bloc can be applied in one coat even though it is thicker. The Mascoat has ingredients that make it lighter weight and it claims that this property makes it a better insulator. They claim the equivalent R value when applied properly will be in the range of R 9 to R 11.

The First Test
Our main initial focus was to test the boxes in cold weather. We believed both products had properties that enhance their performance in hot climates with a lot of radiation from the sun. However, we needed year round performance and Supertherm had claimed their product would absolutely perform as well as conventional insulation in any climate so we were anxious to test cold weather performance first.

Our first test was of all three boxes on March 8th, 2007 with a very moderate starting temperature of sixty-two degrees. The foam box quickly climbed to a much higher temperature (78) than the two ceramic coated boxes, clearly indicating they were loosing considerable more heat. The heat was removed from the foam box and after an additional 1 hour and 14 minutes the ceramic boxes reached 78. During this time the foam box had dropped 4 degrees to 74. The heat was removed from the two ceramic boxes and in only 4 minutes they dropped 2 degrees less than the foam box which had at the heat off for 1 hour and 18 minutes at this point.

It appeared that the claims of Supertherm were greatly exaggerated. Though the Mascoat did not perform any better, they had not claimed that their product would perform at this level.

Preparation for Additional Tests
We immediately contacted Supertherm and did not make any accusations of false claims but rather simply reported the results. They immediately said we must have done something wrong (though we were sure we had not) and asked that we send pictures of the Supertherm box. We took several including close ups and immediately emailed them. They called us back and said he could tell from the photos we had not properly applied the material and that it was apparent to him that it was thin in places. They told us to recoat it again and dry it using a heat lamp and a fan. We purchased a heat lamp, recoated the box inside and out and proceeded to dry and cure the coating as he had instructed. At this point we had used most of a one gallon container over a surface area of approximately 20 square feet—a quantity which they claim will cover 100 square feet.

Meanwhile we decided to add a layer of R 10 foam to the Mascoat box. The Mascoat representative had told us we would get the best results if we combined it with a conventional foam insulation product and since they claimed an equivalency of R-9 to R-11, we thought adding a layer of R-10 foam would be a close comparison. One problem was the R-20 foam box was 4” thicker in each dimension and the additional 2” of foam to the Mascoat box left voids in the corners which would put the Mascoat box at a distinct disadvantage. However, as we did not have any additional foam and wanted to proceed with another test the next morning, we added it leaving the corners void.

One additional modification was made at the suggestion of our engineer. He recommended we put a metal shield around the light bulbs we were using for heat source to negate any reflection of light we might be getting so that the tests would be purely a test of thermal conductivity. Afterwards we realized we should have put the same shield around the heat source in the foam box as it enabled it to heat more quickly.

Second Test
This test was conducted at a slightly colder temperature with only the foam insulated box and the box that now had foam and Mascoat as the Supertherm box was being dried and cured with it’s additional coat.

This test showed the two boxes to be more evenly matched. Surprisingly the Mascoat box initially heated more quickly, requiring only 45 minutes to reach 80 degrees while the foam box required more than double that. This appears to be somewhat skewed and we will perform additional future test. However, as they both began to cool from the same heated temperature the foam box held the heat slightly longer. After a total time of 3 hours that had cooled to approximately the same temperature but the heat had been on in the foam box much longer.

Third Test
After the Supertherm box had been under a heat lamp and fan, being constantly rotated for 3 days (24 hours per day) we decided to once again test all three. In addition it was a much colder morning which should give us a more accurate indicator of cold weather performance.

Because the Supertherm Box had been opened up with the fan running, the interior was much colder than the other two that had remained closed from the previous day and were therefore warmer. And the thick foam box was approximately 10 degrees warmer from overnight than the Mascoat/foam box. The Supertherm box was heated for 48 minutes getting slightly warmer than the Mascoat box and heat was added to it as well. After an additional 22 minutes the three were nearly the same temperature and the heat was turned on in the foam box. The foam box then heated faster than the others and maintained warmer temperatures throughout the next several hours.

The performance of the Supertherm box was so far below the others that we finally stopped checking it as it was very clear that the claims were grossly exaggerated. The Mascoat/foam box lagged only slightly behind the R-20 foam box and the foam box was fully insulated without void corners which gave it an advantage.

We believe if we had filled the corners of the R-10 foam on the Mascoat box and conducted additional test that it would have performed as well at the R-20 foam box which would be in accordance with the claims of the Mascoat manufacturer..

I have been sitting on the side lines for the past 3 years and hope to start a new project within the next few months which will be in a hot climate (South Louisiana). We intend to insulate the walls to R-19 and the roof to R-50. We plan to use the Mascoat Weather Bloc on the exterior walls as I am convinced it will be an excellent supplement (not substitute) as well as providing a long lasting exterior finish that will not need any maintenance. I would encourage any of you that are interested to check them out. You will find them to be very honest and straightforward in their representations and will not make any false claims.

Aug 5, 2010
10:01 AM EDT

Mascoat works
by Engineer in Lousiana

I work as an Engineer in industry in South Louisiana. I had a piece of industrial equipment which I needed to insulate (keep hot) with a thin waterproof insulation. Common industrial insulation practices was not a good fit because it was too thick and allows for water intrusion behind the insulation near the sample ports - this is a corrosion problem.
I chose Mascoat and worked with their engineers in Baton Rouge and Houston to design the product and installation. It is worth noting they do not claim to be appropriate for all applications.
In our case, we applied the material and it is currently dropping ~100F all day every day across insulating coating which is a little bit thicker than the lead of a #2 pencil. This met all of our requirements, and it is maintaining the temperature inside the Centrifuge as well as serving as personnel protection. The Centrifuge is only warm to the touch instead of a burn hazard. Clearly there is some truth to the claims of being a poor thermal conductor.
I would very much like to see more comprehensive independent testing to better understand how and where to best use these materials. If there usefulness is limited to high heat situations such as roof tops or industry, then I want to know. There are more than one wavelength in the realm of "heat". If these materials are insulating at some frequencies and conducting at other frequencies, that does not mean they are without value. notching some frequencies out of a spectrum can reduce the overall energy intensity dramatically.
If Mascoat understands their product as well as it seems, I can understand protecting that knowledge as a trade secret. Other folks who understand less will fumble more applications. I do not assume all the products on the market are the same either. When dealing with sales folks, it is difficult to know what is a knowledge gap and what is deception by omission or just plain lying.
I read the postings above and I have no experience with POWER THERM.
Thanks for the discussion and experiments. I enjoyed the read.

Aug 11, 2010
8:24 AM EDT

More on Ceramic Paint
by George Runkle

I visited a company near me that manufactures this, and there were some interesting properties they showed me, like a steam jenny they had operating had steam going out through a galvanized steel pipe. The part painted with the ceramic paint was cool to the touch. The other demo they had were two little metal boxes under a heat lamp with thermometers inside. One was painted with white paint, the other with their product. The thermometer under the one painted with their product stayed cool.

So, there is something to this, but we need to see some independent research and design guidelines, not manufacturer's hype and revisions of thermodynamics. Right now, my position is that I want to see independent research on this to develop guidelines before I recommend anything like it to my clients.

Post new comment

The content of this field is kept private and will not be shown publicly.
Discussion policy: The editorial staff at GreenBuildingAdvisor.com does review user submissions. Please be respectful of others. Inappropriate content will be removed.
  • Web page addresses and e-mail addresses turn into links automatically.
  • Allowed HTML tags: <a> <em> <strong> <cite> <code> <ul> <ol> <li> <dl> <dt> <dd> <blockquote>
  • Lines and paragraphs break automatically.

* required fields